Modbus Universal MasterOPC Server
Installation
Overview
Delivery Kit Structure
System Requirements
Installing MasterOPC Universal Modbus Server
Installing MasterOPC Universal Modbus Server in Windows 10
Product Activation
Description of Shortcuts
Registration of OPC Servers
Launching the ModRSSim Simulator
Destination and Launching of ModRSSim
Installation of the Null-Modem Emulator
The com0com Distributive
Installing com0com in Windows XP
Description of com0com Shortcuts
Quick Start
Quick Start Destination
Quick Start Destination
QS Abbreviations
Example 1 - Operation Check Using Simulator
QS. Example 1. The Goal
ModRSSim Start and Setup
Inputting a Register Value
QS. Configuring and Launching Modbus OPC Server
QS. Launching MatriconOPC Explorer
Example2 - Device Connection via Modbus RTU
QS. Example 2. The Goal
Creating a Node and a Device
Tag of Analog Input
Tags of Discrete Inputs
Tag of Setpoint
Check in the Run-Time Mode
MasterOPC Universal Modbus Server
Main Characteristics
License Policy
Server Launch
Operation Modes
The Design-Time Mode
Design-Time Interface
Server Configuration
The Menu Area. The ‘Configuration’ Tab
The Menu Area. The ‘General Settings’ Tab
Font Parameters
The ‘Configuration File’ Menu
The ‘Edit’ Menu
The ‘Server’ Menu
The Menu Area. The ‘Help’ Tab
The Menu Area. The ‘Help’ Tab
The Object Tree
Hierarchy of Tree Objects
Operations in the Object Tree
Operations in the Object Tree
Object Renaming
Node Export/Import
Device Export/Import
Subdevice Export/Import
Tag Export
Tag Import
Object Multiplication
Tag Visibility
Tag Availability
Group Operations
Group Operations
Group Operations with Nodes
Group Operations with Devices
Group Operations with Tags
Setting Extra Properties
Parameters of Tree Objects
Parameters of Tree Objects
Operations in Dialogs of Parameters
The Dialog of Server Parameters
The Dialog of Node Parameters
The Dialog of Device Parameters
The Dialog of Subdevice Parameters
The Dialog of Tag Group Parameters
The Dialog of Tag Parameters
The Byte Swapping Editor
Setting the Sequence of Bytes
The Byte Swapping Editor of a Device
The Byte Swapping Editor of a Tag
The Run-Time Mode
Run-Time Interface
Operations in Run Time
The Value Editor
The Server Log
OPC UA-server
OPC UA-server
Server IEC-104
Server IEC-104
MQTT Client
MQTT Client
Description of Built-In Examples
Built-In Configurations
Built-In Configurations
Lua 5.1 Reference Manual
Introduction
Introduction
The Script Editor
The Language and syntax
The Language
Lexical Conventions
Lexical Conventions
Values and Types
Values and Types
Coercion
Variables
Variables
Statements
Statements
Assignment
Control Structures
Cycles while, repeat and for
Function Calls as Statements
Local Declarations
Expressions
Expressions
Arithmetic Operators
Relational Operators
Logical Operators
Concatenation
The Length Operator
Precedence
Table Constructors
Function Calls
Function Definitions
Visibility Rules
Visibility Rules
Error Handling
Error Handling
Function library
Function library
General Concepts of Script Development
String Manipulation
String Manipulation
Patterns
Table Manipulation
Table Manipulation
Mathematical Functions
Mathematical Functions
Input and Output Facilities
Input and Output Facilities
Operating System Facilities
Operating System Facilities
The SERVER Library
Function Invocation
Functions to Operate with Nodes
Functions to Operate with Devices
Functions to Operate with Sub-Devices
Functions to Operate with Tags
Functions to Operate with Ports
Functions to Operate with the Log
Functions to Operate with Reserved Channels
The MODBUS Library
MODBUS Functions
The BIT Library
Bitwise Data Operations
Peculiarities of Bitwise Operations
The TIME Library
Time Operations
The ODBC Library
The ODBC Library
Configuring the ODBC Connector
Functions to Operate via ODBC
The OTHERS Library
SMS Operations
Other Functions
Constants
Constants
The Ggroup Constnts.OPC
The Group Constants.LUA
Additional functions
Additional functions
JSON
JSON
Examples and Other Useful Things
Example 1. Processing a quality
Problem Statement
Creating Tags
Creating a Script
Data Conversion
Division of a Numerical Value to Digits
The BCD Format
The Float Format
Examples of Calculations of Checksums
CRC-CCITT
DCON
Operation via ODBC
Writing to OPC HDA Archive Database
LuaSQLite3 Reference Manual
LuaSQLite3 Reference Manual
SQLite3 Functions
Database Methods
Methods for Prepared Statements
Methods for Callback Contexts
Numerical Error and Result Codes
The Linux runtime system
Description
Install
Description
Loading the runtime system
Install
Running
Working with an OPC server
Creating and Loading Configuration
Copying and running the configuration
TCP and COM port forwarding
Update the runtime system
Description
DCOM Configuration
Preview
DCOM Configuration in Windows XP SP2
Launch of DCOM Configuration Utility
Default Properties
Default COM Security Parameters
Application Parameters
Description of the Mod_RSSim Simulator
Purpose and Features
Documentation from Developer
Simulator Usage
Use of the Simulator together with Modbus Universal MasterOPC
Operation via the Modbus RTU Protocol
Operation via the Modbus TCP Protocol
Simulator GUI
Operation Tools
Launch from a Command Line
Configuration Dialogs
Modbus Ethernet Configuration
RS-232 Configuration
Animation Configuration
Noise Configuration
Extra Parameters of MODBUS Emulation
Script Automation
Script Automation
Simulator API
Language Help
Description of the com0com Emulator
Destination of com0com
Notes on com0com Installation
com0com. Setup
Use of COM0COM, ModRSSim and Modbus Universal MasterOPC
Appendices
Information about Manufacturer
Information about Manufacturer